S30M-V1B features

The ORVIBO S30M-V1B single-outlet meter uses BL2028N / BK7231N and HLW8032. See common functions for operation and automation and remote display for power rules and M1 fields.

On this page

Power restoration: off / on / restore

RC5 supports off, on and restore.

In Settings → General → Power-on policy, choose:

Policy Output after power restoration / reboot
Off (default) Off
On On
Restore Last successfully saved relay state

Restore saves relay state, not an in-progress automation timer. A physical short press acts first and saves in the background, so an immediate power cut may lose that last press. Remote and automatic changes save the state before switching output; a failed save leaves output unchanged. Selecting restore captures the current output. Upgrading old community settings preserves networking, authentication, names, calibration and energy, and maps the existing on / off policy without changing its meaning.

Red and blue indicators

The following applies while normal indicators are enabled:

State Blue Red
Wi-Fi connected; MQTT unconfigured or ready Steady on for output on, off for output off Off
Wi-Fi configured but disconnected Continues to show output state Fast blink, about 150 ms on and off
Wi-Fi connected; configured MQTT not ready Continues to show output state Slow blink, about 1 second on and off
No network configured and not connected Alternates with red, about 500 ms per color Alternates with blue

Disabling indicators turns off these normal indications. Holding the button overrides them with timing feedback, even when indicators are disabled or child lock is enabled.

Local button and child lock

A short press toggles the relay. Child lock blocks ordinary short presses, not recovery gestures or hold-time feedback. Remote control waits for about 1.5 seconds after a short press. Recovery instructions are under common functions → recovery.

Metering

The HLW8032 provides voltage, current, active power and accumulated energy. Real-time fields appear only with valid samples. Missing samples or fields not updated for about 5 seconds appear as unavailable, which must not be interpreted as zero load power.

The default voltage, current and power multipliers are 1.894288 / 1.0102 / 1.88835008906368, extracted from fixed conversion constants in this model's stock 2M.1220 firmware. Use independent reference instruments when adjusting calibration.

Open Settings → General → Calibration to edit the three multipliers separately. Each accepts a finite value from 0.001 to 100, retaining the full decimal precision shown above. Saving applies the values immediately and keeps them after a restart. Calibrate with a stable load, comparing each measurement against independent reference instruments. “Calibrated” only means that calibration parameters have been saved by a user.

Upgrades replace the old 1.88 / 1 / 1.88 defaults only when they have never been saved as a calibration. Manually saved multipliers, other combinations and accumulated energy are preserved. A Wi-Fi reset keeps the multipliers; a factory reset restores the stock model defaults above. Energy is saved about every 5 minutes, when settings are saved and before a normal restart. Sudden power loss may lose roughly the latest 5 minutes of accumulated energy.

If output is on but readings remain unavailable, check metering validity rather than increasing coefficients to create a reading. Power off and remove the load before inspecting meter wiring. Mains must be disconnected before reconnecting UART or external DC power.