Daikin air quality monitor (G2)
G1 has no formaldehyde expansion port; G2 adds it. G3 adds a display and uses separate firmware; see the G3 guide. The default name DAIKIN G1/G2 is historical; custom names are preserved. The BRY88AX151K download target is verified on G2 BRY88AB151K. G1 BRY88AA151K compatibility remains unconfirmed, so installation is not documented.
The verified G2 ESP32 / 4 MB Flash board uses BRY88AX151K firmware that detects PM2005 / PM2105 and the optional formaldehyde module. Its web interface shares M1 reading cards, comfort scales and linked-device information, with local access, IoTCloud and Home Assistant support.
Choose the latest compatible stable release for everyday use; RC builds are for beta testing. See the release notes for availability, version requirements and cumulative changes.
| Generation | Model | Current image compatibility |
|---|---|---|
| G1 | BRY88AA151K | Compatibility unconfirmed; installation is not documented |
| G2 | BRY88AB151K | Verified ESP32 / 4 MB board using the universal BRY88AX151K target |
| G3 | BRY88BBA15G | Display-equipped; separate ESP32 and screen MCU images |
See stock backups for the original G2 UART backup and recovery formats.
On this page
Readings and controls
- Temperature and humidity use the model recovered from this unit’s stock firmware: temperature is reduced by 4.9 °C; humidity is corrected through the mixing ratio and corrected temperature, then bounded to 0–100%. In General settings, customize the temperature subtraction (default 4.9 °C) and humidity adjustment (default 0 %RH), or restore defaults. Saved values apply immediately and survive restart. Positive temperature offsets lower readings; negative offsets raise them. Humidity follows the corrected temperature.
- Read PM2.5, PM10, CO₂, temperature, humidity and TVOC. PM2005 / PM2105 provide both particulate readings in one frame; the interface displays separate cards in one row; PM10 stays hidden when it is unavailable. The CO₂ module needs about three minutes to warm up; the interface reports no valid reading during this period.
- Supporting firmware adds Settings → General → CO₂ module diagnostics and calibration, with raw readings, status bytes, communication errors and calibration results. The current legacy compatibility profile retains reserved status bytes without decoding fault flags, which remain unknown. Manual calibration requires a known reference concentration of 400–1500 ppm, stable for at least two minutes. Outdoor air is not necessarily 400 ppm. After calibration, compare subsequent readings against the reference. A missing acknowledgement is reported as an unknown outcome and is not retried automatically.
- Formaldehyde is detected automatically. Without the module, its card and entity stay hidden. A previously detected module that stops responding becomes invalid; old readings never become zero measurements.
- Comfort scales follow fresh readings. Stale values do not contribute to comfort ratings. TVOC uses the module's native ppb unit, with a ventilation reference of ≤300 ppb independent of custom indicator thresholds. Particulate display bands follow HJ 633—2026 table 3; these instantaneous readings are not a calculated AQI.
- Configure the name, network, web password and indicators in Settings. Hold the rear button for five seconds to reopen the setup hotspot without clearing settings.
The OLED and internal GPIO26 indicator are currently unused. Existing hardware tests and the original UART backup use BRY88AB151K. Select stock AA/AB backups by their actual model.
Stock compensation and particulate power saving
Matching firmware and frontend versions apply the stock PM2.5, CO₂ and formaldehyde curves. The web interface, MQTT, indicators and A1 automation use the same compensated readings. Published ranges are 1–300 µg/m³ for PM2.5, 400–3000 ppm for CO₂ and 0.01–0.5 mg/m³ for optional formaldehyde; diagnostics retain raw measurements. TVOC keeps the sensor's actual ppb readings, including zero, with humidity compensation and valid baseline restoration.
The PM module uses the stock dynamic measurement mode. After startup, a reading updates only after at least 36 seconds and a valid completed measurement. Normal particulate readings remain valid for 120 seconds. Enable intermittent operation under General settings → Night particulate power saving; it is disabled by default. The preset is 23:00–07:00, UTC+8, with editable times and time zone. Equal start and end times disable the window. Before time synchronization, dynamic measurement continues.
During the night window, measurement runs for about 59 seconds every 59 minutes. PM2.5 and PM10 update after a complete sample; measurement stops between these windows. Night readings remain valid for up to one hour while their displayed sample age keeps increasing. This reduces nighttime operation, but A1 also responds later to new particulate changes. Leave night power saving disabled when prompt automation is needed.
Upgrade A1, M1 receivers and the frontend together to use the one-hour validity. Only the particulate sample lifetime is extended; communication failures still expire under the existing short timeouts, so an offline device does not remain an online data source.
Indicator settings
Open Settings → General → Indicator rules and enable the air quality indicators. CO₂, TVOC and PM each support up to two thresholds with steady on, always off, fast blink or slow blink. Select either PM2.5 or PM10 as the PM lamp's data source; only the selected measurement controls that lamp. Formaldehyde rules are available when its module is detected. Rules survive a restart. The highest matching threshold wins within a measurement; unmatched or stale readings turn its output off. TVOC / formaldehyde share one lamp, with priority given to fast blink, slow blink, steady on, then off.
The Wi-Fi lamp indicates system status: three long and three short pulses when unconfigured; fast blink when Wi-Fi is disconnected (150 ms on/off); slow blink when configured MQTT is not ready (1 s on/off); steady on when ready. MQTT can remain unconfigured without preventing readiness. This lamp is independent of the air quality indicator switch.
First installation
Choose a release that explicitly includes DAIKIN on the downloads page. Do not substitute another model's image when an older archive lists only Phicomm devices. Existing 0.9.x archives provide the full image only. v1.0.0 also provides a separate hub variant.
- Confirm the ESP32 / 4 MB Flash board and wiring, then back up the entire original Flash. Keep that backup private because it contains network credentials.
- Hold GPIO0 / BOOT0 low while powering on to enter the ESP32 bootloader. Use ESPTool to write
daikin_BRY88AX151K.all.binat 0x0. Never upload the factory image through web OTA. - Release BOOT0 and power cycle. Join
BRY88AX151K-AP-<last six MAC digits in uppercase>(for example,BRY88AX151K-AP-AABBCC) and openhttp://192.168.0.1/to configure Wi-Fi. The hotspot uses the same name and address when reopened by the button or after a network failure. - Find the device IP in your router and check the local readings. Allow CO₂ to warm up; no formaldehyde card appears without its module.
Use ESP32-compatible 3.3 V serial signals and avoid back-powering the device from a USB serial adapter. Review Before flashing if wiring is uncertain. A complete image or backup restore overwrites Flash; confirm the device and file first.
Updates and recovery
Historical releases may still use the phicomm_daikin prefix. Use the filenames listed on that release’s download page and in SHA256SUMS.
Upload daikin_BRY88AX151K.ota.bin.signed from the firmware update page. The device verifies the project signature, target and image before installing; Wi-Fi and MQTT settings remain. RC6 supports online checks and downloads. If an older version lacks this entry, update with a local signed package first. G1/G2 do not use G3 screen, font or firmware files.
An explicitly labelled unsigned recovery input accepts a trusted raw application image. Releases name it daikin_BRY88AX151K.ota.bin.raw; local builds use daikin_BRY88AX151K.ota.bin. If the web interface is unavailable, enter the BOOT0 bootloader again and restore the original backup or a complete image. See Firmware updates.
IoTCloud, Home Assistant and A1
Follow Connect to IoTCloud using an MQTT account on the selected node. The device is discovered as DAIKIN G1/G2, and the platform provides the same reading cards as its local interface. Home Assistant discovery publishes only sensors that are present.
Add this device's MAC and optional IP in the updated A1 settings. MQTT under the same account grants reading sessions automatically. A1 prefers local reads and uses MQTT measurements when local reads are unavailable. The monitor's linked-purifier area shows A1 devices that have actually read it; a grant alone is not a connection.
A1 offers automation sources according to currently valid data, independently of the monitor model. Missing formaldehyde or stale readings hide the corresponding options while preserving saved rules. If required control data is unavailable, A1 uses its configured offline speed. TVOC is not currently a fan-control metric.
Hub edition
The hub uses a separate hub image. v1.0.0 name synchronization, metering and model support require matching frontend and target-device versions; see the release notes. The old sensor interface is incompatible; use matching source-device and M1 receiver versions.
The hub discovers devices through mDNS, communicates over paired UDP, and forwards upstream MQTT and Bemfa messages. Local Home Assistant and MQTT clients use an external broker. The full edition remains a sensor device.
Select Hub management on the device page, or open http://DEVICE-IP/iotcloud/#/. The hub uses the device web administration password and session. With no password, it opens directly. With a password, sign in once; switching between the control and hub pages in the same tab reuses the session. Change the password in device settings, and select Sign out to end the session.
After upgrading to rc.5, the separate hub password is retired. The existing hub username, device list, forwarding and pairing settings are retained. The hub username remains the topic namespace. Configure UDP device-pairing passwords and external MQTT broker credentials separately.
The DAIKIN itself appears automatically in the hub device list. Paired-device parameters and controls use the hub UDP transport, so the browser only needs to reach the hub. TC1 / S30 cards show power and hide expired meter readings. Remote pages expose supported controls and diagnostics. Open the target device’s local page for network settings, administration passwords, automation, upgrades and backups.
In Hub management, select a discovered LAN device, check its model, ID and IP, and pair using that device's management password. Confirm and pair again if its IP changes. Move devices previously connected to the hub's embedded broker to an external broker.
You can also register S30M-V1B through the management API and pair it at a specified IP across subnets where mDNS is unavailable. The hub uses that address after authenticating the session.
Apple Home uses experimental HAP bridging, off by default. Enable it under Apple Home to obtain the pairing code. Matter is unavailable.
After receiving new device and socket names, the hub notifies the home controller to refresh its configuration. Existing pairings are retained.
Each TC1 / S30 switch synchronizes its device-side socket name. Change socket names in device settings; the hub refreshes them automatically. Socket ConfiguredName is read-only; renaming in Apple Home remains a client-local alias. Device names synchronize to HomeKit. A1, M1 and DAIKIN also accept ConfiguredName writes through the hub, with persistence and readback confirmation. These name and metering features require hub v1.0.0 or newer and target devices running rc.6 or a newer compatible release. Names follow each device’s UTF-8 byte limit: 31 bytes for TC1, 63 for A1, M1, DAIKIN and S30. Pairings and device identities are retained. Use device settings when you want to change the shared device name.
A1 purifiers and fresh-air variants use the standard AirPurifier service for power, speed and automatic/manual mode. Upgrades assign this service a separate identity from the former Fan service while preserving pairing and existing control characteristic identities. The first TC1 / S30 switch also exposes whole-device power (W) and cumulative energy (kWh) using Eve custom characteristics. Apple Home does not display these custom power / energy characteristics. Third-party clients supporting Eve characteristics can read them. HAP provides the data but cannot add a reading card to Apple Home. Device and hub web pages show power; S30 also shows voltage, current and cumulative energy.
A1 uses an air-purifier icon when displayed separately. When grouped with a light, Apple Home may select the light as the primary service; Apple Home controls the grouped tile icon. Display the services separately to keep the air-purifier tile. G3 exposes valid sensors through the hub.
Switch from full to hub
Only newer full firmware that advertises this operation provides the conversion option. The image must fit the device's actual OTA slot. Use local HTTP and a real signed hub OTA file; 0.9.x full images do not provide this feature.
- Open the device on your LAN. A web administration password is optional; if one is configured, use it to authenticate.
- Open Settings → Firmware → Advanced, select the matching signed
hubOTA file and enable Switch to hub firmware. This option cannot be combined with unsigned recovery. - Select Upload and install, review the confirmation and explicitly approve the conversion. Wi-Fi, MQTT and the web administration password are retained.
- Reopen the device after restart, confirm its variant is
hub, select Hub management, and reuse the same web administration session if a password is configured. HomeKit is off by default; enable it separately when needed.
Normal signed updates and unsigned recovery still accept only the current variant. Direct OTA from hub → full is unsupported.