Start at Firmware & resources and choose the latest compatible release for your device with its matching checksums. Pinned versions below are reproducible examples; stated minimum versions, stock versions and migration-tool requirements still apply.

For the M1 with the original EMW3080B / MK3080B Wi-Fi module. Use only M1 firmware files. For installation over Wi-Fi, see M1 stock OTA.

Read Before flashing. Disconnect mains, original supplies and loads, use a stable independent 3.3 V supply, and back up the complete Flash before writing. A full image overwrites the bootloader, original firmware and some settings.

Recommended: serial Bootloader. The module UART pads are easy to solder, and many users already have a USB-TTL adapter. J-Link is an alternative.

On this page

Choose a method

Method Requirements
Serial bootloader 3.3 V USB-TTL and YMODEM software; original bootloader must work. No J-Link is required
J-Link J-Link plus OpenOCD (Windows / Linux); validates and writes full-image segments for first installation / recovery.
Product J-Link full image Input for preparing serial images
M1 monitor phicomm_m1.all.bin phicomm_m1.ota.bin.raw

Download the correct product and verify SHA256SUMS from that release. .ota.bin / .ota.bin.signed are signed web-update packages, not full images or directly transferable serial user applications.

Bootloader flashing

Use a 3.3 V, 921600-baud USB-TTL adapter, independent 3.3 V supply and YMODEM-capable terminal. Retain the original sensor controller.

Wiring and download mode

EMW3080B serial bootloader pins

Module pin Connection
16, VCC Independent 3.3 V
17, GND Supply negative and USB-TTL GND
9, user UART TX USB-TTL RX
10, user UART RX USB-TTL TX
19, BOOT Ground during download; release afterward

Cross TX / RX. This is the user UART, not the log UART. If another board controller drives module RX, isolate its output first to avoid two TX drivers.

Wire with power off and BOOT low. Use 921600, 8N1, no flow control, then power on. Wait for MXCHIP>. If it does not appear, check power, ground, TX / RX and BOOT; never send erase commands blindly. This method preserves the original bootloader and applies only to the menu and partition layout below.

1. Confirm the menu and partition map

Select the USB-TTL port with 921600, 8N1, no hardware or software flow control. Enter ?:

1:FWUPDATE     Update MiCO
2:USERUPDATE   Update user APP
5:MEMORYMAP
6:BOOT

Enter 5 and verify the key partitions. These are Flash offsets, not CPU-mapped addresses.

ID Partition Start Length
2 Bootloader 0x00000000 0x00013000
3 MiCO Kernel 0x00013000 0x000b5000
6 User Application 0x00088000 0x00040000
7 PARAMETER1 0x000c8000 0x00004000
8 Parameter backup, also labeled PARAMETER1 0x000cc000 0x00004000

The MiCO region includes the user application, at offset 0x75000 from MiCO's start. Stop if the menu or map differs. This procedure does not write the bootloader, parameters, ATE, OTA Storage or USER Storage. Replacing the kernel / application still replaces factory firmware; preserving those regions does not replace a full backup.

2. Prepare serial images

Verify the product's raw OTA file against the release checksums. The script fixes model = 'm1'. Never send .all.bin to menu 1 or 2, or an unconverted OTA file to menu 2.

Raw .ota.bin.raw contains 0x75000 bytes of kernel / padding, then the user application and a 16-byte MD5 trailer. FWUPDATE needs contiguous kernel / application data without the MD5 trailer. USERUPDATE needs the application including its 8-byte length / CRC header.

Run this in the firmware directory, using only a verified raw image, never a signed web package. It checks length, MD5, application magic, ABI, product and CRC before producing the two serial files:

python3 - <<'PY'
from pathlib import Path
import binascii
import hashlib
import struct

model = 'm1'
image = Path(f'phicomm_{model}.ota.bin.raw').read_bytes()
offset = 0x75000
assert offset + 144 <= len(image) <= offset + 0x40000 + 16, 'Invalid image length'
assert hashlib.md5(image[:-16]).digest() == image[-16:], 'OTA MD5 mismatch'
length, reserved, crc, magic, stack, abi = struct.unpack_from('<IHHIII', image, offset)
assert 120 <= length <= 0x40000 - 8, 'Invalid application length'
assert len(image) == offset + 8 + length + 16, 'Invalid application boundary'
assert magic == 0xc89346 and abi == 3, 'Application magic or ABI mismatch'
user = image[offset:-16]
assert reserved == crc == binascii.crc_hqx(user[8:], 0), 'Application CRC mismatch'
product = f'PHICOMM_{model.upper()}_EMW3080'.encode() + b'\0'
assert product in user, 'Image product does not match model'
Path('fw.serial.bin').write_bytes(image[:-16])
Path('user.serial.bin').write_bytes(user)
print('Kernel + application:', len(image) - 16, 'bytes')
print('User application:', len(user), 'bytes; SHA256:', hashlib.sha256(user).hexdigest())
PY

Record the resulting file lengths and compare them to the device's reported Size. Lengths and hashes vary by firmware; use your downloaded file's results.

3. Send and read back

  1. At MXCHIP>, enter 1. Wait for Waiting for the file to be sent / C, then send fw.serial.bin with YMODEM CRC, 1 KiB packets. Use a 50 ms packet interval where supported; readback verification is still required.
  2. Wait for Successfully! and check Size. This confirms only the bootloader's receive / write report, not that the application can boot.
  3. Enter 2 -r and use Receive YMODEM to save USER.bin. It must contain the complete 0x40000 user partition: 262144 bytes. Exit minicom with Ctrl-A, Q before a Linux script takes exclusive access. Never let two programs read / write the serial port simultaneously.
  4. Compare the application-length prefix against user.serial.bin and validate its CRC:
python3 - <<'PY'
from pathlib import Path
import binascii
import hashlib
import struct

expected = Path('user.serial.bin').read_bytes()
readback = Path('USER.bin').read_bytes()
assert len(readback) == 0x40000, 'User partition readback length mismatch'
actual = readback[:len(expected)]
assert actual == expected, 'Application readback mismatch; do not boot; write and read back again'
length, reserved, crc = struct.unpack_from('<IHH', actual)
assert length + 8 == len(actual), 'Application length mismatch'
assert reserved == crc == binascii.crc_hqx(actual[8:], 0), 'Application CRC mismatch'
print('Application bytes and CRC match; SHA256:', hashlib.sha256(actual).hexdigest())
PY
  1. Only after matching readback, enter 6 to boot. Release BOOT from ground before a normal power cycle; restore original wiring as described in the preparation guide.

4. Recover an application CRC failure

user firmware invalid [-3] means the user application CRC failed.

  1. Reenter the bootloader, verify checksums and regenerate the same firmware's user application file.
  2. Enter 2 and send user.serial.bin via YMODEM with a 50 ms packet interval. A matching product .usr.bin is also valid if verified identical to the extracted result.
  3. After Successfully!, run 2 -r and compare readback with the script above.
  4. If bytes differ, check power, ground, wiring, exclusive port access and the USB-TTL adapter, then rewrite and read back. Preserve the bootloader and parameters; never use whole-chip erase as trial and error.
  5. Enter 6 only when the application bytes match exactly.

5. Confirm application execution

Booting....... means the bootloader is starting the application. A running M1 switches the user UART to 115200, 8N1, no flow control. Staying at 921600 produces garbled text. At 115200, hex mode shows this 12-byte sensor query about every five seconds:

23 01 00 00 00 00 00 00 00 00 00 21

Module pads

M1 can use wires soldered to its module pads. Check orientation by pin numbers.

EMW3080B SWD pins

Module pin Connection
1 or 3, SWD_CLK J-Link SWCLK, standard 20-pin pin 9
2 or 4, SWD_DIO J-Link SWDIO, standard pin 7
16, VCC Independent 3.3 V and J-Link VTref, standard pin 1
17, GND Common supply negative and J-Link GND, standard pin 4

VTref is a sensing input, not a power output. Do not connect J-Link's 5 V output. Use signal labels for compact programmers rather than assuming standard pin numbers. SWD flashing does not require grounding BOOT.

Standard J-Link SWD connector

Prepare OpenOCD and the helper scripts

Use OpenOCD + J-Link over SWD. No mlink / mflash application is needed. Windows uses the legacy OpenOCD included in the tool package; Linux uses OpenOCD 0.11 / 0.12 with the new configuration. Both need the matching flash_prog.elf; installing stock OpenOCD and running program all.bin is insufficient.

Download and extract into a short working path, such as C:\phicomm or ~/phicomm:

  • EMW3080 helper scripts: Python 3 validation, splitting and flashing helper, plus a modern OpenOCD configuration.
  • zA1 3080_JLINK tool package: retain openocd/, sflash_write.tcl and flash_prog.elf, and rename the outer directory to 3080-tool. Do not run its old firmware or batch files.
  • Your product's .all.bin and SHA256SUMS from the same release. Signed web packages and other products are not accepted.

Extract the helper files into the working directory, outside 3080-tool:

phicomm/
  emw3080.py
  mx1290-modern.cfg
  phicomm_m1.all.bin
  SHA256SUMS
  3080-tool/
    flash_prog.elf
    sflash_write.tcl
    openocd/
      win32/openocd_mico.exe
      scripts/interface/jlink_swd.cfg
      scripts/target/MX1290/...

Back up before writing. The helper does not provide complete Flash backup or factory restoration. Use an appropriate full-read tool first if factory recovery is required. The old package's sflash_read_file has argument and external-command problems and must not be used as a cross-platform backup command. The connection check identifies the debug interface without writing Flash. The flash command overwrites the bootloader, kernel, application and ATE.

Windows: install, check and flash

  1. Install Python 3 version 3.9 or newer. Confirm py -3 --version works.
  2. OpenOCD accesses J-Link through libusb. If it already detects J-Link, keep the driver. For LIBUSB_ERROR_NOT_SUPPORTED, follow the OpenOCD Windows instructions and use Zadig to install WinUSB for J-Link only. SEGGER applications may need their original driver restored afterward.
  3. With power off, connect SWD, VTref, common ground and independent 3.3 V power. Power the module and close other J-Link applications. Open PowerShell in the working directory and check the connection:
cd C:\phicomm
py -3 .\emw3080.py check --tool-dir .\3080-tool --engine legacy

Look for approximately 3.3 V Vref, a SWD ID and MX1290.cpu, followed by a successful exit. Fix wiring, power or driver problems before proceeding.

For M1:

py -3 .\emw3080.py flash .\phicomm_m1.all.bin --model m1 --checksums .\SHA256SUMS --tool-dir .\3080-tool --engine legacy

For M1:

Linux: install, check and flash

On Debian / Ubuntu:

sudo apt update
sudo apt install openocd python3
openocd --version
cd ~/phicomm
python3 emw3080.py check --tool-dir ./3080-tool --engine modern

Use OpenOCD 0.11 / 0.12. This mode loads the helper's mx1290-modern.cfg, not the legacy package's MX1290.cfg. For USB permission errors, check your distribution's OpenOCD udev rules and group permissions, log in again and reconnect J-Link. Install equivalent packages and USB rules on other distributions.

For M1:

python3 emw3080.py flash phicomm_m1.all.bin --model m1 --checksums SHA256SUMS --tool-dir ./3080-tool --engine modern

Use --openocd /absolute/path/openocd if OpenOCD is outside PATH. The Linux configuration supports the newer DAP interface; this procedure remains experimental.

Split files and verify flashing

Before accessing J-Link, flash validates the release SHA256, product, image boundaries, application CRC and embedded raw OTA MD5, then splits and writes the image. Validation failure exits without erasing. Only this project's current .all.bin layout is supported. Original tool files are also checked to prevent mixing in a programmer for another board.

To split without connecting a device (replace python3 with py -3 on Windows):

python3 emw3080.py split phicomm_m1.all.bin --model m1 --checksums SHA256SUMS --output firmware

The output directory must not exist; existing files are never overwritten.

Output Full-image range (end exclusive) Programmer partition ID Offset within partition
boot.bin 0x000000–0x012000 (72 KiB) 1 0x0
ota.bin 0x013000–0x0C8000 (724 KiB including padding) 2 0x0
ate.bin 0x0D0000–end of file (up to 256 KiB) 3 0x0

The split ota.bin is for this SWD process only; do not upload it to the web updater. The three writes exclude 0x012000–0x013000 and parameters at 0x0C8000–0x0D0000. Partition IDs are not raw Flash addresses. Never change the three 0x0 arguments to 0x13000 or 0xD0000.

The helper runs these operations using erase-as-needed and programmer post-write verification, without whole-chip erase:

sflash_write_file firmware/boot.bin 1 0x0 MK3080B 0
sflash_write_file firmware/ota.bin 2 0x0 MK3080B 0
sflash_write_file firmware/ate.bin 3 0x0 MK3080B 0
reset run
shutdown

flash uses an automatically cleaned temporary directory. Every chunk must return Result: OK and OpenOCD must exit successfully. Verify after write failed, Error during Write or a nonzero exit means failure: stabilize power and repair the connection before rewriting. Then check normal boot, provisioning and device functions as described below.

Problem Action
Missing flash_prog.elf / tool hash mismatch Point --tool-dir at the original package root and retain its matching files; do not substitute another board's ELF
target requires -dap Use --engine modern with the included mx1290-modern.cfg for newer OpenOCD
couldn't bind to socket The helper uses 23333 / 24444 / 26666. Check occupied or Windows reserved ports with netsh interface ipv4 show excludedportrange protocol=tcp
Legacy Named pipes currently not supported Use numeric ports; do not set legacy gdb_port to disabled
Verification succeeds but no setup hotspot Power off, remove programming wires, restore normal wiring and power; check the product image and collect boot logs if necessary. Do not try whole-chip erase

Finish and provision Wi-Fi

  1. Power off, release BOOT ground if used and remove programming wires.
  2. Restore original wiring, reassemble, then reconnect the normal supply.
  3. Join M1-AP-<last six MAC digits> and open http://192.168.0.1/.
  4. Verify model and connectivity. Check the sensor readings and screen. Configure MQTT if needed and confirm connection.

See M1 operation and firmware updates. Module wiring and serial procedures reference the MXCHIP EMW3080 flashing guide.