Documentation navigation

简体中文 · English

Firmware updates

Start at Firmware & resources and choose the latest compatible release for your device with its matching checksums. Pinned versions below are reproducible examples; stated minimum versions, stock versions and migration-tool requirements still apply.

This page covers web OTA after community firmware is installed. Factory devices need their model-specific procedure, including M1 factory Wi-Fi setup and installation or A1 factory Wi-Fi setup and installation. M1 first migration requires the full native OTA image from 0.9.21 or newer. Factory interfaces do not accept the community signature wrapper.

Choose the latest compatible stable release for everyday use; RC builds are for beta testing. Read the release notes and check the tag, model and variant. Supporting firmware checks and installs RC releases through a separate candidate channel. Download manually when older firmware lacks that entry. Candidates do not replace the stable channel.

M1 has two MCUs. This page updates the EMW3080 Wi-Fi module, not the ATSAMD20G18A sensor controller. Dual-region user readings and double-click actions require the companion open-source controller v1.0.0-rc. See controller features for older features’ minimum versions and follow the separate controller update steps.

On this page

Update after installing a migration snapshot

The TC1 mico_ota.bin and the old Daikin daikin-bry88ab.application.bin attachments are fixed migration snapshots. After Wi-Fi setup, continue to the version listed in Downloads: TC1 uses phicomm_tc1_a1.ota.bin.signed; the old Daikin 0.9.21-2cfd89-dirty first needs a local WebUI upload of the full daikin_BRY88AX151K.ota.bin.raw. Once running a version supporting signatures, use .ota.bin.signed. Obtain firmware and SHA-256 from the same release and verify the installed version after reboot.

Check for updates on the device

RC6 builds for A1, M1, TC1 and Daikin provide GitHub Pages HTTPS and domestic/international HTTP update sources. Choose a source in the firmware settings and check:

  • The UI distinguishes a new version, already up to date and network failure.
  • Switch sources and retry if a network request fails.
  • Check the model, version and release notes, then explicitly download and install. Checking never installs an update automatically.

You can read release notes for the selected version. Use Cancel download during transfer; cancellation, network timeout or failure restores normal services. A retry starts from the beginning. Cancellation is unavailable after the final commit starts.

Source Address
GitHub Pages https://phicomm-io.github.io
China mirror http://phicomm.fjrcn.cn
International source http://phicomm.fjrcn.com

Compare changes across releases

Open the website's Release Log upgrade comparison and choose the model, firmware variant, current version and target release. The page summarizes cumulative changes along the release chain and reports when incomplete records prevent comparison.

Optionally enter a LAN address and read the device information once. The web management password is used only for that request; manual selection remains available if reading fails. A comparison never checks for or installs firmware. Older device pages retain their original single-release notes.

Choose the correct file

This table covers A1, M1, TC1 and DAIKIN. S30M-V1B updates through an .rbl URL; see S30 updates.

File Purpose
.ota.bin.signed Signed OTA package for web upload and MQTT / URL installation; P-256 / SHA-256 signature verification is mandatory
.ota.bin.raw Native image for an explicitly supported first migration or unsigned recovery; factory M1 migration uses the full image from 0.9.21 or newer
.all.bin Full image for wired flashing; never upload it as OTA

Use the GitHub archive on the project downloads page, choose your exact product and verify SHA256SUMS from that release. The device verifies the header signature before erasing, and activates the new image only after Flash readback SHA-256 and compatibility checks pass.

Install a local file

A1, M1, TC1 and DAIKIN also accept a downloaded file through the device WebUI:

  1. Open its firmware update page.
  2. Select and upload the verified .ota.bin.signed file.
  3. Keep power connected throughout writing and the automatic reboot.
  4. Reopen the WebUI and check the running version.

Unsigned recovery from older community firmware may use .ota.bin.raw under its specific procedure. Firmware supporting that option accepts it after selecting Allow unsigned firmware. Factory M1 uses the separate factory upload procedure; later normal updates still use signed packages.

Recovery

Updates pause linkage and other business responses while keeping update status and cancellation available. Reduce concurrent web and MQTT access during updates.

If the WebUI is reachable, check the file, model, version and network, then retry. If the device cannot boot, use the corresponding wired recovery guide: TC1, M1 · A1, DAIKIN.

Full and slim firmware

DAIKIN BRY88AX151K provides ordinary full and separate hub images in v1.0.0-rc.6. Both detect PM2005 / PM2105 and the optional formaldehyde module. RC6 supports online checks, downloads and local files. G3 uses a separate model and update manifest. Normal OTA must match the current variant. Use the hub conversion procedure for full → hub; direct hub → full OTA is unsupported.

Default files include the complete device UI. Files containing -no-frontend-resources keep an offline setup page for Wi-Fi, initial MQTT settings and the web password, available through the device hotspot or LAN address. Use local device management or IoTCloud for full controls and settings. Both share the same appearance. MQTT is not required to complete Wi-Fi setup.

Online checks stay on the current firmware variant. To switch variants manually, select the signed package for the same physical product.

For screen MCU/font updates and original programs, see the G3 guide and stock backups.