Daikin BRY88AB151K: migrate through stock OTA
In Firmware & resources, select the latest compatible stable release for Daikin air quality detector (G1/G2), the full variant and Native OTA. The stock sender accepts newer images meeting the format and size limits below; installing the old 0.9.21-dirty transition image first is unnecessary. RC builds are for beta testing.
Choose your computer’s operating system below. Checking the file and uploading will both show matching commands. On Windows, use PowerShell; on macOS or Linux, use Terminal. Without JavaScript, all commands remain visible.
On this page
1. Prepare the device and computer
Use a stable device power supply and a computer with 2.4GHz Wi-Fi and Python 3. The sender needs only the Python standard library. Download the files before switching the computer to the device hotspot. Ethernet can keep the computer online while Wi-Fi connects to the device, but internet access is not required during flashing.
Have a recovery method available. For a first attempt, keep your own complete 4MB serial Flash backup. Another device's complete backup can overwrite identity and private settings.
Stock OTA listens on TCP 8555 after entering update mode. It writes the inactive application slot, selects it for boot, and restarts. Entering OTA mode already initializes and erases the inactive slot. Keep power connected.
2. Download and check the files
- Python sender.
- In Firmware & resources, select Daikin G1/G2, the latest compatible stable release and the
fullvariant. Downloaddaikin_BRY88AX151K.ota.bin.rawandSHA256SUMSfrom that same release. Use the actual published filename if it differs.
Keep all three files in one directory. Stock installation requires a native application image, not .all.bin, a full-flash backup, .ota.bin.signed, the hub variant or G3 firmware. Each stock application slot is 1,572,864 bytes (1.5 MiB); that limit remains after migration. The sender checks SHA-256, ESP32 image format and size.
Replace SHA256_FROM_MANIFEST below with the 64-character SHA-256 on the daikin_BRY88AX151K.ota.bin.raw line in your downloaded SHA256SUMS. Do not reuse the old tutorial image's digest.
Open a terminal in the download directory and check the file without contacting the device.
Windows PowerShell:
py -3 .\daikin_stock_ota.py .\daikin_BRY88AX151K.ota.bin.raw --sha256 SHA256_FROM_MANIFEST --check-only
macOS / Linux:
python3 ./daikin_stock_ota.py ./daikin_BRY88AX151K.ota.bin.raw --sha256 SHA256_FROM_MANIFEST --check-only
Install Python 3 first if unavailable. Stop on a hash, format or size mismatch and check the model, variant and matching checksum manifest.
3. Trigger stock OTA with the button
With the stock application running, locate the RESET pinhole on the back of the device. Use a suitable thin tool to gently press the button inside, then follow this sequence:
- Hold for approximately 3 seconds, then release for approximately 0.5 seconds.
- Hold for approximately 3 seconds, then release for approximately 0.5 seconds.
- Hold for approximately 3 seconds, then release.
Each hold must fall between approximately 2 and 5 seconds. Keep each release-to-next-press gap below 2 seconds. Do not replace the sequence with one long hold or hold beyond 5 seconds. This sequence started the mode 0 OTA task on the test device.
In some stock provisioning states, a long hold clears settings and restarts the device instead. The code checks an internal wififlag; this gesture is not guaranteed to preserve settings in every mode. If the device restarts or the gesture fails, observe its state rather than repeatedly extending the hold time.
If a serial console is available, success includes:
Start OTA Task Suceess, mode 0
app_ota_server_create success
Serial access is useful for diagnosis but is not required for the wireless transfer itself.
4. Connect to the stock hotspot
Select the device's daikin! hotspot using the computer's Wi-Fi menu. For this stock version, the default hotspot password is 12345678.
The tested SSID was daikin!f76748f9; the suffix varies by device. Check your own device identity. The tested STA MAC was 9c:9c:1f:f7:67:48 and its AP BSSID was 9c:9c:1f:f7:67:49.
The test computer received 192.168.4.2/24 through DHCP, with device/gateway 192.168.4.1. Keep this connection even if the OS reports no internet. Do not reuse the device's old router-assigned address, and prevent automatic switching to another Wi-Fi network.
On Windows, use the Wi-Fi menu when possible. In the remote SSH test, a current-user netsh profile returned 0x57; an all-users profile for this hotspot worked. Do not delete unrelated network profiles.
5. Probe the accepted version label
Stock firmware accepts only a version label higher than its current version. The old fixed .16 label therefore fails on newer devices. Stay on the device network and probe an explicit range without an image:
py -3 .\daikin_stock_ota.py --probe-versions SV.02.00.01.16 SV.02.00.01.32
python3 ./daikin_stock_ota.py --probe-versions SV.02.00.01.16 SV.02.00.01.32
The scan waits 2 seconds between attempts and stops immediately on ToDo, an unexpected response, a timeout or another communication error. It sends only handshake/version headers: 0 firmware bytes, no End or checksum, no Wi-Fi switching and no automatic upload.
For example, if .16 through .20 return b'No' / EOF and .21 returns b'ToDo' / complete, use .21 as the first accepted label in the upload command.
Use the first accepted label explicitly in the separate upload command below; change the example .21 to your result. If communication failed, resolve it before trying another command.
6. Upload the application
Confirm that the computer is connected to your device's hotspot, then run the sender. Its default destination is 192.168.4.1:8555.
Windows PowerShell:
py -3 .\daikin_stock_ota.py .\daikin_BRY88AX151K.ota.bin.raw --sha256 SHA256_FROM_MANIFEST --version SV.02.00.01.21
macOS / Linux:
python3 ./daikin_stock_ota.py ./daikin_BRY88AX151K.ota.bin.raw --sha256 SHA256_FROM_MANIFEST --version SV.02.00.01.21
--version is the stock protocol admission label, not the community firmware version; it does not modify the image. The uploader requires this explicit choice and never reuses a probe result automatically. Confirm the image's model, layout and SHA-256 independently.
Expected output includes:
Kit2 Version Up -> Okey
SV.02.00.01.21 -> ToDo
ACK .../<image bytes> (...%)
Final response: b'OK'
Wait for the final OK and reboot. The sender waits for each length ACK and separates End from the final checksum. This service is not an HTTP upload endpoint: do not replace the sender with curl or combine protocol messages into one write.
7. Verify the community application
After boot, join the open hotspot BRY88AX151K-AP-<last six MAC digits in uppercase> and open http://192.168.0.1/. Check the model, device ID and that the version matches your selected download, then configure router Wi-Fi, a management password and MQTT. Once connected to your router, use its assigned IP.
Check readings after sensor warm-up. CO₂ may take longer; devices without a formaldehyde sensor have no HCHO reading.
The stock bootloader and partition table remain, and the application starts from the second slot at 0x190000. Configure Wi-Fi again on first boot. Later images must still fit the stock 1.5 MiB slots.
If you already installed 0.9.21-dirty from the old guide
The old daikin-bry88ab.application.bin attachment is a fixed 0.9.21-2cfd89-dirty snapshot. It is not the current release. Join its DAIKIN-<last six MAC digits> hotspot, open http://192.168.4.1/ and configure router Wi-Fi first.
From Downloads, obtain the latest compatible stable Daikin G1/G2 full image, daikin_BRY88AX151K.ota.bin.raw, and its matching checksums. Verify it and install it through the old WebUI's local firmware upload. That old version accepts a native application image; after installing a version supporting signatures, use .ota.bin.signed for normal updates as described in Firmware updates. Keep power connected. After reboot, check the version, sensor readings and network settings. The new recovery hotspot and address follow the format at the start of this section.
8. Troubleshooting and recovery
| Symptom | Action |
|---|---|
| No hotspot | Check model/version, normal stock boot and gesture timing. The OTA task does not necessarily create an AP in every configuration state. |
| Hotspot connects but TCP 8555 times out/refuses | Check network switching and the actual gateway. Inspect the two OTA startup log markers if available. |
| Handshake or version rejected | Use the handshake-only scan in section 5. Select an accepted label explicitly for upload, and check image compatibility separately. |
| Transfer interrupted, invalid ACK or final NG | Save the output and observe the powered device. Wait for reboot and confirm the community version before another update. |
| OK but no new hotspot | Wait for reboot, rescan and inspect the device startup logs. |
| Device will not boot | Stop repeated wireless update attempts and seek serial recovery using your own complete Flash backup. |