  "contract": "sensor-values-v3",
  "status": "implemented-unreleased",
  "wire_schema": 3,
  "encoding": "MessagePack",
  "metadata_topic": "phicomm/v2/<scope>/sensor/<device_id>/metadata",
  "state_topic": "phicomm/v2/<scope>/sensor/<device_id>/state",
  "descriptor_identity": [
    "device_id",
    "boot",
    "descriptor_revision",
    "field_id",
    "type",
    "unit"
  ],
  "state_retained": false,
  "metadata": "Retained descriptor map; numeric fields use strict name/type/unit; state refers to matching descriptor_revision. TTL is a sample property, not metadata.",
  "sample_max_age_ms": {
    "optional_fields": [
      "pm25",
      "pm10"
    ],
    "minimum": 1,
    "maximum": 3600000,
    "missing": "existing short timeout",
    "g12_normal": 120000,
    "g12_night": 3600000
  },
  "freshness": "Require real source age + receiver elapsed < max_age_ms, and receiver elapsed below existing communications lease (A1 15s; frontend/M1 at most20s or configured shorter). Replayed/retained state never renews communications. Preserve counters and full snapshot invalidation.",
  "compatibility": "Additive contract documents current schema3 split metadata/state. Frozen schema2 remains unchanged. Strict older schema3 consumers may reject extended PM samples and need updating before night operation.",
  "runtime_validation": [
    "Extended fields must bind to number and µg/m³ metadata",
    "age_ms must be strictly below max_age_ms",
    "All non-PM fields retain short age rules",
    "Unknown metadata/type/unit, missing or invalid fields revoke old numeric values without losing configuration",
    "Broker session/availability expiry is independent of source age"
  ],
  "lan": {
    "envelope_version": 3,
    "optional_body_property": "pm25_max_age_ms",
    "ages_index": 2,
    "slots": [
      "temperature",
      "humidity",
      "pm25",
      "formaldehyde",
      "co2"
    ],
    "note": "No PM10 slot. Other envelope, token, identity, replay and integer-unit rules unchanged."
  },
  "pm_power": {
    "action": "config.set",
    "section": "pm_power",
    "defaults": {
      "enabled": false,
      "start_minute": 1380,
      "end_minute": 420,
      "timezone_minutes": 480
    },
    "interval": "Local [start,end), crossing midnight allowed; equal start/end means inactive; invalid time uses dynamic measurement",
    "sampling": "mode5 at startup and outside night; night mode1 off, 59000ms policy interval, every60th step mode5 for59000ms; first36000ms after enable cannot produce a new accepted measurement",
    "cache": "Source timestamp only advances on an eligible complete, checksum-correct successful sample. Ordinary age limit120000; active night3600000. Module fault/TTL expiry invalidates sample."
  },
  "diagnostics": "Raw PM, CO2, HCHO and climate inputs remain separate from corrected business values; diagnostic registry additions are append-only. SGP baseline private cache is not transferable user configuration."
}